Electrorotation (ROT) offers one such route to capture cellular properties by inferring permittivity and conductivity from a cell’s movement in an electric field. This allows the characterization of the cell type and state by profiling its frequency-dependent rotational movement under a modulated electric field.
However, there are limitations. The challenge is that the capture, measurement, and replacement of cells is quite cumbersome and lowers the throughput of ROT platforms, where throughput refers to the number of cells that a given technology can analyze at any given time.
Recently, researchers from Tokyo University of Science (TUS) developed a continuous flow ROT (cROT) to address conventional ROT’s drawbacks. The new platform leverages microfluidics to continuously measure cellular dynamics and simultaneously capture cells to collect measurements on one device. The group’s validated findings were recently published in Lab on a Chip.
“I discovered that cancer cells had vastly different responses to electric fields while they looked similar. This implied a certain degree of individuality, and the idea of discerning the differences using ROT intrigued me,” explains Dr. Masahiro Motosuke, a Professor in the Department of Mechanical Engineering at TUS and the project’s Principal Investigator. “However, gathering accurate data using ROT requires the precise placement and removal of a single cell, and I wanted to make the process of analyzing many cells easier.”
The researchers fabricated the new device with redesigned interdigitating electrodes that induce cell rotation and a microchannel for cell passage. The electrode geometry increases the number of cells that can be analyzed and reduces the time required to replace a cell as measurements are collected.
The electrical field applied within the microchannel enables analyzing rotational behavior from a continuous flow of cells. Together, these improvements increase the automated system’s throughput. The research team validated the system’s accuracy by obtaining cell membrane permittivity and cytoplasm conductivity measurements from HeLa cells, a human cell line commonly used in research.
“We significantly increased measurement throughput to 2,700 cells per hour with our cROT technique,” says Prof. Motosuke about the report’s most significant findings. “Furthermore, the device does not require precise cell manipulation and takes advantage of rapid image processing when processing the cells’ electrical data,” he adds further. Other advantages of the new system are its high degree of automation and ease of installation or removal.
The cROT device indeed demonstrates a remarkable enhancement in throughput when contrasted with traditional ROT platforms. While conventional ROT techniques typically process 10 to 20 cells per hour, the cROT system achieves an impressive throughput of 2,700 cells per hour, which is more than 100 times higher. Furthermore, the cROT system significantly minimizes the time necessary for cell replacement.
Prof. Motosuke envisions a promising future for the cROT system that the team has developed. “With our cROT technique, we’ve unlocked the ability to delve into the subtle intricacies of single-cell dynamics, including aspects like cell physiology, the state of the cell membrane, and the concentration of intracellular ions,” he says.
He anticipates that the swift and accurate analyses offered by this cutting-edge approach will be a catalyst for substantial advancements in the realms of cancer drug development, diagnosis, and novel cell-based therapies. This breakthrough technology opens doors for collaboration and adoption by prominent players in the oncology industry, potentially revolutionizing the way we combat cancer.
More information:
Kazuma Yoda et al, Continuous-flow electrorotation (cROT): improved throughput characterization for dielectric properties of cancer cells, Lab on a Chip (2023). DOI: 10.1039/D3LC00301A
Citation:
Noninvasive technology for the high-throughput characterization of cancer cells (2023, December 11)
retrieved 11 December 2023
from https://medicalxpress.com/news/2023-12-noninvasive-technology-high-throughput-characterization-cancer.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.